Located in Camberwell, Victoria, a state-of-the-art facility provides
a robust, reliable and secure environment for hosting.
The network room includes over 400 square metres of raised floor,
sophisticated temperature and humidity control, an array of physical
security features, state-of-the-art smoke detection and fire suppression
systems, motion sensors, closed circuit video monitoring and 24
x 7 secured access. Redundant subsystems including multiple Internet
connections, power on the premises and backup generator provides
the highest levels of reliability.
|
|
| |
|
|
| |
[
Hosting Prices / Rates - Click Here ] |
|
| |
|
Power Redundancy |
|
Network |
The
facility is connected to its own mains power substation within
the building. In case of interruption to mains power, backup
power is supplied by both 60KVA and 40KVA UPS supported by
a 350KW Turbo Charged V12 Generator with over 2500 litres
of diesel on site, enabling the facility to seamlessly power
through any extended interruption to main power.
Each rack is individually connected on its own 10AMP socket
and circuit breaker, so power to our/your equipment will not
be affected if another customer's equipment 'throws a breaker'.
|
|
We
only use Cisco switches and routers for internal networking
and Internet connections. Each 'head end' rack is connected
to a core switch by gigabit fibre. In case of failure, each
rack is also connected by 100BaseT to a secondary switch. |
| |
|
|
| Bandwidth |
|
Air
Conditioning |
The
Internet connectivity is provided through the high speed local
backbones and international links of several suppliers (including
Connect, UUNet and Netspace). Through these suppliers we use
a number of peering traffic exchange points throughout Australia.
Our paths to the Internet are fully redundant, using several
telco providers and entries to our building. In the event
of an outage on one path the connection will switch to another
path.
We pay extremely close attention to bandwidth usage, ensuring
capacity exceeds demand. |
|
The environment within the
facility is constantly monitored and air conditioned using
dual Leibert 70KWA under floor air conditioning systems, maintaining
both temperature and humidity. The workload is shared across
both units but can be maintained by a single unit if required. |
| |
|
|
| Cabling |
|
Fire
Protection |
Data and electrical
cables are run in separate trays within the raised floor space
to prevent interference between data with power. |
|
We use state-of-the-art VESDA
smoke detection, installed in the ceiling and floor. Vesda
'sniffs' the air, using a laser to detect particles of smoke
long before a human could detect it. In case of failure, a
secondary smoke detection system is fitted throughout the
facility. |
| |
|
|
| Security |
|
|
The
building and network room within are independently secured.
A closed circuit video system records all access to the facility.
Lockable front and rear doors on each cabinet provides additional
security for equipment and cables. |
|
|
| |
|
|
| |
|
|
|
|
| |
|
|
| |
|
|